0%
Drilling and Column Pipe Installation Rules

Drilling and Column Pipe Installation Rules

Drilling and Column Pipe Installation Rules

  • Well drilling - drilling and pipe - pump installation operations should be carried out by qualified and expert persons with professional competence and equipment.
  • Under no circumstances should the wells be cleaned and developed by giving high air pressure with a compressor.
  • PVC Drilling Pipes are required to comply with TS11794 standard.
  • A ground survey should be carried out before drilling a borehole.
  • Drill pipe and column pipe should be selected according to the pump to be used. The diameter of the well to be drilled must be suitable for the drill pipe.
  • Pipes should not be hit against each other and the ground. They should not be dragged away.
  • Pipes should be checked before being lowered into the well and defective pipes should not be used.
  • Pipe male thread covers should not be removed until the moment of installation.
  • During installation, the threads of the pipes should be smeared with soft soap to facilitate grooving.
  • Grease and similar oils should not be applied to the threads of the pipes during installation.
  • When grooving the pipes, a rubber tightening wrench should be used.
  • Wrenches that can damage the pipe such as chain wrenches should not be used while grooving the pipes.
  • If drill pipes get stuck while lowering into the well, they should not be continued. Pipes should be removed and lowered after re-dredging with drilling tools.
  • In order for the drill pipes to stand upright in the well, they should be pulled up and suspended at least 10 cm after they touch the bottom.
  • Graveling should be done slowly and evenly around the pipe to avoid bridging during graveling.
  • The submersible pump should be installed below the dynamic level.
  • Submersible pumps should be positioned above the level of the filtered pipe. Otherwise, the submersible pump may draw in sand and the pipelines on the surface may be damaged in a short time.
  • The pump column pipe should be fixed on the metal stand pipe, not on the drill pipe

SDR

Pipe Depth Classification

Pipe Critical Collapse Pressure

SN

 

 

Pkr (Bar)

kN/m²

21

100 m Series

7.7

27

17

300 m Series

14.8

55

13.5

500 m Series

32

112

Important: Please pay attention to Critical Collapse Pressure values and installation rules in pipe selection. Otherwise, our company may not be held responsible for Well, Pipe and Pump damages.

Contact Us

Let’s Determine the Right Solution for Your Projects Together

Get a Quote